{"product_id":"vapura-32-automatic-nucleic-acids-extraction-instrument","title":"VaPura 32-Automatic nucleic acids extraction instrument","description":"\u003ch1\u003eVaPura 32 Automated Nucleic Acid Extraction System\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e Product Description  \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVaPura 32 is a high-throughput and high-precision automated nucleic acid extraction system used together with prepackaged extraction reagents based on silica-coated superparamagnetic beads to extract and purify nucleic acids from blood, tissue, cells, body fluids, bacteria, viruses, and other biological samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system purifies and enriches nucleic acids by utilizing magnetic rods to capture, transfer, and release magnetic beads. Featuring a highly automated, fast, and simple workflow, VaPura 32 is an ideal solution for molecular diagnosis and animal disease detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeatures  \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eSimple \u0026amp; Efficient Workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eSimply add the sample and start the preset program. VaPura 32 performs fully automated nucleic acid extraction with a one-button operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHigh Extraction Efficiency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eRecovery rate is higher than 95%, supported by strong magnetic force adsorption of magnetic beads and permanent magnet technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEffective Contamination Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe built-in UV module and filtered fan system help reduce the risk of contamination during operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePower Failure Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eIf power is interrupted during operation, the system resumes the extraction process after restart, helping prevent sample loss caused by unexpected power failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Parameters  \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe technical specifications below summarize the key operating parameters of the VaPura 32 automated nucleic acid extraction system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"0\" cellspacing=\"0\" height=\"572\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"231\"\u003e \u003ccol width=\"418\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"48\" class=\"firstRow\"\u003e\n\u003ctd class=\"et2\" height=\"36\" width=\"232\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"496\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eVaPura 32\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et3\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePrinciple\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"496\"\u003e\n\u003cp\u003e\u003cspan\u003eMagnetic Beads Method\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSample throughput\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"496\"\u003e\n\u003cp\u003e\u003cspan\u003e1～32\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCompatible consumables\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"496\"\u003e\n\u003cp\u003e\u003cspan\u003e96 deep well plate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProcessing volume \/μL\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e20～1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"44\"\u003e\n\u003ctd class=\"et5\" height=\"33\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDifference between \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003epurification repeats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003eCV≤5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHeating temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003eRoom temperature～120℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTemperature accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e±1℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperation interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e8-inch color touch screen,can be connected to external mouse\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInternal procedures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e500 programs can be stored\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProgram management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003eAdd,edit,save as,delete,program mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstrument interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e3 type A USB,1 Ethernet port,1 DB9 debug interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNetwork\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003eWi-Fi function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDisinfection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003eUV disinfection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum input power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e500 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDimensions(W×D×H)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e412 mm×410 mm×430 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"32\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"214\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWeight(kg)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"476\"\u003e\n\u003cp\u003e\u003cspan\u003e30 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWorkflow  \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAutomated Nucleic Acid Extraction Workflow\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/vazyme-singapore-website-prod.s3.ap-southeast-1.amazonaws.com\/83fcf386804a40b39d0d9f58252fc56b\" alt=\"Automated nucleic acid extraction workflow of VaPura 32 including sample preparation, plate loading, program start, extraction and product collection.\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVaPura 32 provides a fast, simple, and highly automated workflow for nucleic acid extraction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eStorage  \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eStorage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 15–25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTransportation: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eRoom temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"qu-list\"\u003e\n\u003cdiv class=\"list open\"\u003e\n\u003cdiv class=\"listask\"\u003e1: What is VaPura 32 used for?\u003c\/div\u003e\n\u003cdiv class=\"listres\"\u003e\n\u003cp\u003eVaPura 32 is designed for automated nucleic acid extraction and purification across a broad range of research applications, including genomics, infectious disease research, NIPT projects (cfDNA), plant science, and FFPE tissue analysis and other molecular biological researches.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qu-list\"\u003e\n\u003cdiv class=\"list open\"\u003e\n\u003cdiv class=\"listask\"\u003e2: What sample types are compatible with VaPura 32?\u003c\/div\u003e\n\u003cdiv class=\"listres\"\u003e\n\u003cp\u003eVaPura 32 supports blood, animal tissue, cultured cells, plants (leaves, roots, seeds, fruits, fungi), body fluids, swabs, FFPE tissue sections, stool, soil, and other biological samples.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qu-list\"\u003e\n\u003cdiv class=\"list open\"\u003e\n\u003cdiv class=\"listask\"\u003e3: How does the system purify nucleic acids?\u003c\/div\u003e\n\u003cdiv class=\"listres\"\u003e\n\u003cp\u003eThe VaPura System employs magnetic bead-based extraction technology. Integrated magnetic rods adsorption, transfer, and release magnetic beads through sequential lysis, wash, and elution steps, enabling fully automated nucleic acid purification without the need for pipetting, centrifugation or vacuum manifolds.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qu-list\"\u003e\n\u003cdiv class=\"list open\"\u003e\n\u003cdiv class=\"listask\"\u003e4: What contamination control features does the VaPura 32 include?\u003c\/div\u003e\n\u003cdiv class=\"listres\"\u003e\n\u003cp\u003eYes. VaPura 32 is equipped with an integrated UV decontamination system designed to minimize cross-contamination between runs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"qu-list\"\u003e\n\u003cdiv class=\"list open\"\u003e\n\u003cdiv class=\"listask\"\u003e5: How does VaPura 32 respond to a power interruption?\u003c\/div\u003e\n\u003cdiv class=\"listres\"\u003e\n\u003cp\u003eVaPura 32 resumes operation after power is restored, helping avoid sample waste caused by unexpected power failure\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AstorScientific","offers":[{"title":"Default Title","offer_id":67764363493453,"sku":null,"price":15000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0568\/5883\/7069\/files\/1-2101599001799884802.png?v=1792635529","url":"https:\/\/www.astorscientific.us\/products\/vapura-32-automatic-nucleic-acids-extraction-instrument","provider":"AstorScientific","version":"1.0","type":"link"}