{"product_id":"microplate-reader-bmrw-201","title":"Microplate Reader BFA-8601","description":"\u003cdiv class=\"blp-panel-heading\"\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/div\u003e\n\u003cul class=\"blp-feature-list\"\u003e\n\u003cli\u003eDiverse types of carriers:\u003c\/li\u003e\n\u003cli\u003eSuitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of choices to meet your experimental needs. The cuvette mode has independent cuvette software, which can be directly used for photometric detection, kinetic or spectral scanning, and standard curve establishment. The ultra trace detection plate is designed for rapid detection of small volume samples. Supports simultaneous analysis of up to 16 samples. Users can quickly and conveniently clear the tested samples for continuous measurement.\u003c\/li\u003e\n\u003cli\u003eWide and accurate lighting system:\u003c\/li\u003e\n\u003cli\u003eUsing a flickering xenon lamp as the light source, wavelength selection is carried out through an advanced grating monochromator system. The wavelength detection range is 200~1100 nm, and full spectrum scanning can be performed in 1 nm steps. The self check function of the instrument during startup checks key components such as the light source, detector, and carrier position to ensure stable and reliable operation of the instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"blp-panel-title-row\"\u003e\n\u003cdiv\u003e\n\u003ch3 id=\"blpFeaturesTitle\"\u003eProduct Features\u003c\/h3\u003e\n\u003cp\u003eKey design, performance, usability, and safety advantages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"blp-feature-rich\"\u003e\n\u003cp\u003eDiverse types of carriers:\u003c\/p\u003e\n\u003cp\u003eSuitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of choices to meet your experimental needs. The cuvette mode has independent cuvette software, which can be directly used for photometric detection, kinetic or spectral scanning, and standard curve establishment. The ultra trace detection plate is designed for rapid detection of small volume samples. Supports simultaneous analysis of up to 16 samples. Users can quickly and conveniently clear the tested samples for continuous measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Diverse-types-of-carriers-Suitable-for-96-well-plates-384-well-plates-ultramicro-plates-and-cuvette-with-a-variety-of-BFA-8601-i-3-Biolab.webp\" alt=\"Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of\" title=\"Diverse types of carriers: Suitable for 96 well plates\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Diverse-types-of-carriers-Suitable-for-96-well-plates-384-well-plates-ultramicro-plates-and-cuvette-with-a-variety-of-BFA-8601-i-4-Biolab.webp\" alt=\"Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of\" title=\"Diverse types of carriers: Suitable for 96 well plates\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Diverse-types-of-carriers-Suitable-for-96-well-plates-384-well-plates-ultramicro-plates-and-cuvette-with-a-variety-of-BFA-8601-i-5-Biolab.webp\" alt=\"Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of\" title=\"Diverse types of carriers: Suitable for 96 well plates\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Diverse-types-of-carriers-Suitable-for-96-well-plates-384-well-plates-ultramicro-plates-and-cuvette-with-a-variety-of-BFA-8601-i-6-Biolab.webp\" alt=\"Diverse types of carriers: Suitable for 96 well plates, 384 well plates, ultramicro plates, and cuvette, with a variety of\" title=\"Diverse types of carriers: Suitable for 96 well plates\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eWide and accurate lighting system:\u003c\/p\u003e\n\u003cp\u003eUsing a flickering xenon lamp as the light source, wavelength selection is carried out through an advanced grating monochromator system. The wavelength detection range is 200~1100 nm, and full spectrum scanning can be performed in 1 nm steps. The self check function of the instrument during startup checks key components such as the light source, detector, and carrier position to ensure stable and reliable operation of the instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Wide-and-accurate-lighting-system-Using-a-flickering-xenon-lamp-as-the-light-source-wavelength-selection-is-carried-out-BFA-8601-i-7-Biolab.webp\" alt=\"Wide and accurate lighting system: Using a flickering xenon lamp as the light source, wavelength selection is carried out\" title=\"Wide and accurate lighting system: Using a flickering xenon lamp as\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eEquipped with incubation and oscillation functions:\u003c\/p\u003e\n\u003cp\u003eEquipped with incubation function, the average temperature difference between wells is ±0.5°C at room temperature +4°C~65°C and 37°C. The oscillation frequency of linear oscillation mode is divided into low, medium, and high gears for users to choose from.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Equipped-with-incubation-and-oscillation-functions-Equipped-with-incubation-function-the-average-temperature-difference-BFA-8601-i-8-Biolab.webp\" alt=\"Equipped with incubation and oscillation functions: Equipped with incubation function, the average temperature difference\" title=\"Equipped with incubation and oscillation functions: Equipped with\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePowerful and rich software programs:\u003c\/p\u003e\n\u003cp\u003eA fully functional data analysis software that can meet the vast majority of data processing needs. Built in multiple data processing methods, including quantitative curve fitting, qualitative analysis, dynamic calculation, custom equations, and four parameter fitting, and supports customized services for customers. Calculation methods can be added according to customer needs. Data can be exported to Excel with just one click, and detailed result reports can also be generated through built-in tools.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Powerful-and-rich-software-programs-A-fully-functional-data-analysis-software-that-can-meet-the-vast-majority-of-data-BFA-8601-i-9-Biolab.webp\" alt=\"Powerful and rich software programs: A fully functional data analysis software that can meet the vast majority of data\" title=\"Powerful and rich software programs: A fully functional data analysis\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eSimple and convenient operation mode:\u003c\/p\u003e\n\u003cp\u003e10.1-inch touchscreen display, capable of completing the entire testing process on a single machine, easy to operate, simple and user-friendly, with a graphical interface design and simple program editing. Various testing programs can be preset. 2 USB ports and 1 Ethernet port, supporting USB data export or connection to a computer.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Simple-and-convenient-operation-mode-10.1-inch-touchscreen-display-capable-of-completing-the-entire-testing-process-on-a-BFA-8601-i-10-Biolab.webp\" alt=\"Simple and convenient operation mode: 10.1-inch touchscreen display, capable of completing the entire testing process on a\" title=\"Simple and convenient operation mode: 10.1-inch touchscreen display\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUser Interface:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/User-Interface-Main-Interface-Microplate-Reader-10-inch-high-resolution-capacitive-touch-screen-Xenon-flash-lamp-Number-BFA-8601-i-11-Biolab.webp\" alt=\"User Interface: Main Interface Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp \/ Number\" title=\"User Interface: Main Interface Microplate Reader 10 inch\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003eMain Interface\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Parameter-settings-Microplate-Reader-10-inch-high-resolution-capacitive-touch-screen-Xenon-flash-lamp-Number-of-flashes-BFA-8601-i-12-Biolab.webp\" alt=\"Parameter settings Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp \/ Number of flashes \u0026gt;\" title=\"Parameter settings Microplate Reader 10 inch high-resolution\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003eParameter settings\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Board-layout-interface-Microplate-Reader-10-inch-high-resolution-capacitive-touch-screen-Xenon-flash-lamp-Number-of-BFA-8601-i-13-Biolab.webp\" alt=\"Board layout interface Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp \/ Number of\" title=\"Board layout interface Microplate Reader 10 inch high-resolution\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003eBoard layout interface\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/biolabscientific.com\/content\/images\/BFA-8601\/Settings-interface-Microplate-Reader-10-inch-high-resolution-capacitive-touch-screen-Xenon-flash-lamp-Number-of-flashes-BFA-8601-i-14-Biolab.webp\" alt=\"Settings interface Microplate Reader 10 inch high-resolution capacitive touch screen Xenon flash lamp \/ Number of flashes \u0026gt;\" title=\"Settings interface Microplate Reader 10 inch high-resolution\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003eSettings interface\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"blp-panel-title-row\"\u003e\n\u003cdiv\u003e\n\u003ch3 id=\"blpSpecificationsTitle\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eDetailed operating and construction parameters for this model.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"blp-spec-table-wrap\" role=\"region\" aria-label=\"Technical specifications\" tabindex=\"0\"\u003e\n\u003cdiv class=\"blp-specifications\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBFA-8601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10 inch high-resolution capacitive touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eXenon flash lamp \/ Number of flashes \u0026gt; 10^9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength range\u003c\/td\u003e\n\u003ctd\u003e200-1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength repeatability\u003c\/td\u003e\n\u003ctd\u003e0.2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical system\u003c\/td\u003e\n\u003ctd\u003eGrating monochromator, 1 nm stepper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading range\u003c\/td\u003e\n\u003ctd\u003e0 - 4.0 OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier type\u003c\/td\u003e\n\u003ctd\u003e96 well plate, 384 well plate, microplate, cuvette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette size (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e12.5 mm x 12.5 mm x 40-45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection system\u003c\/td\u003e\n\u003ctd\u003e2 silicon photoelectric detection tubes, 1 measurement, 1 reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear @450nm\u003c\/td\u003e\n\u003ctd\u003eR² ≥ 0.999, [0.0 - 3.0 Abs]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy @450nm\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 0.003 Abs), (0-2.0 Abs); ±2.0%, (2.0-2.5 Abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of absorbance @450nm\u003c\/td\u003e\n\u003ctd\u003ePrecision mode: CV \u0026lt; 0.5% or SD \u0026lt; 0.003; Quick mode: CV \u0026lt; 1.0% or SD \u0026lt; 0.003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure speed\u003c\/td\u003e\n\u003ctd\u003e96 well plate for 8 seconds; 384 well plate for 15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOscillation\u003c\/td\u003e\n\u003ctd\u003eLinear, with 3 adjustable speeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003eRoom temperature +4°C to 65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C @ 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.5°C @ 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput power\u003c\/td\u003e\n\u003ctd\u003eAC 100-240V, 3A, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e250V, 3A Φ5x20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxDxH)\u003c\/td\u003e\n\u003ctd\u003e300 mm x 430 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AstorScientific","offers":[{"title":"Default Title","offer_id":67827738312781,"sku":"BFA-8601","price":7528.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0568\/5883\/7069\/files\/Microplate-Reader-10-inch-high-resolution-capacitive-touch-screen-Xenon-flash-lamp-Number-of-flashes-10-9-BFA-8601-i-1-Biolab.webp?v=1793166432","url":"https:\/\/www.astorscientific.us\/products\/microplate-reader-bmrw-201","provider":"AstorScientific","version":"1.0","type":"link"}